INSTALLATION AND MOUNTING This device can operate without any user interface, but normal application is with Dixell CX660 keyboard. The HOT-KEY connector can be used to connect X-REP display (Depending on the model).ģ.
Dixell cx 660 manual serial#
The optional direct serial output RS485 (ModBUS compatible) permits a simple XWEB interfacing. The device is equipped with the HOT-KEY connector that permits to be programmed in a simple way. Finally, the XM678D is equipped with the three digital inputs (free contact) fully configurable by parameters. Moreover, fifth and sixth probe are used to evaluate and control the superheat. The device is also equipped with six probe inputs: for temperature control, for control the defrost end temperature, for display and the fourth can be used for application with virtual probe or for inlet/outlet air temperature measurement. The XM678D is provided with 6 relay outputs to control the solenoid valve, defrost - which can be either electrical or hot gas - the evaporator fans, the lights, an auxiliary output and an alarm output and with the stepper valve driver. It can be inserted in a proprietary LAN with up to 8 different sections which can operate, depending on the programming, as stand alone controllers or following the commands coming from the other sections. GENERAL DESCRIPTION The XM678D is a microprocessor based controller for multiplexed cabinets suitable for applications on medium or low temperature. FT1) in parallel with inductive loads could be useful.Ģ. In case of applications in industrial environments, the use of mains filters (our Ensure that the wires for probes, loads and the power supply are separated andįar enough from each other, without crossing or intertwining. Consider the maximum current which can be applied to each relay (see (see address) with a detailed description of the fault. In case of failure or faulty operation send the instrument back to the distributor or Fit the probe where it is not accessible by the End User. Warning: disconnect all electrical connections before any kind of maintenance. Limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation Do not expose to water or moisture: use the controller only within the operating Check the application limits before proceeding.ġ.2 SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. The instrument shall not be used for purposes different from those described
Dixell cx 660 manual manual#
7ġ.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument forĮasy and quick reference.
Dixell cx 660 manual how to#
HOW TO PROGRAM THE PARAMETERS (PR1 AND PR2).
Dixell cx 660 manual driver#
In case of fault in the thermostat probe the start and stop of the compressor are timed through.1592023030 XM678D GB r1.3 2011.07.05.doc XM678D 1/14ĬONTROLLERS FOR MULTIPLEXED CABINETS WITH STEPPER DRIVER INSIDE Push and immediately release the SET key or wait about 5s to return to normal visualisation. Consider the maximum current which can be applied to each relay see Technical Data. An additional parameter “FS” provides the setting of temperature, detected by the evaporator probe. With FC parameter it can be selected the fans functioning.
![dixell cx 660 manual dixell cx 660 manual](https://pholod.com.ua/files/uploads/Catalogy/Dixell/Manual_Dixell_CX660.jpg)
Md and two defrost modes: Norlake Dixell Xr06Cx Progra mmed to To memorise the new set point value push the SET key again or wait 10s. Amazon Advertising Find, attract, and engage customers. This is used to make sure circulation of air only if his. TEMPERATURE CONTROLLERS-Dixell Refrigeration Controllers Please make sure that you are posting in the form of a question. To change the parameter’s value operate as follows. For warranty information about this product, please click here.
![dixell cx 660 manual dixell cx 660 manual](https://climate.emerson.com/resource/image/3843102/landscape_ratio2x1/1180/590/d417d3dc13c4dedbe1b0fb828d38d451/dV/h002-dixell.jpg)
Dixell cx 660 manual download#
To print the manual completely, please, download it. Press the “SET” key to display its value. Share your thoughts with other customers.
![dixell cx 660 manual dixell cx 660 manual](https://pholod.com.ua/files/uploads/_Dixell_CX660.jpg)
At the end of defrost.įit the probe where it is not accessible by the End User. Amazon Inspire Digital Educational Resources. Amazon Renewed Refurbished products with a warranty. Amazon Rapids Fun stories for kids on the go.īe the first to review this item. Two stages digital controllers with multi probe input 4 pages. DIGITAL CONTROLLER WITH DEFROST AND FANS MANAGEMENT. View and Download Dixell XR06CX operating manual online. Find great deals for Temperature Controller Dixell Xr06cx 2 NTC Probes.